| Open
Space, Area and Height Limitations |
Exterior Open Space- Provision for open
space at the front side and rear of the building shall be as given in
Appendix-N
Building shall be a set block of at least
3.00m from internal means of access in a layout of buildings.
Building Abutting Two or More Streets
- When a Building abuts two or more streets, The setbacks from the
streets shall be such as if the building was fronting each such street.
Open Spaces to be Provided for the
Full Consumption of F.S.I .- The open spaces to be left at the
sides and rear shall confirm to the height necessary to consume full
F.S.I. permissible for the occupancy in the zone, provided that smaller
open spaces than area required under regulation No. 15.1 would be
permissible if the height of the building is restricted permanently to
any smaller height. The Authority may permit smaller set back and permit
additional floor area to the limit of 10 sq.m. on upper floor to consume
permissible F.S.I. to avoid structural difficulties or great hardship,
but so as not to affect adversely the light and ventilation of adjoining
building or part thereof.
Open Spaces Requirements - Side or rear open space in relation to the height
of the building for light and ventilations-
1) Residential and Commercial zones
a) building having length/depth
upto 40 m. The Open spaces on all sides except the front side of a
building shall be of a width not less than one third of the height of
that building above the ground level rounded to the nearest decimeter
subject to a maximum of 20 m. the minimum being 3.00 m. for a
residential building and 4.5 m. for a Commercial building.
Building with Length/Depth Exceeding
40 m.
a) If the length or depth of
building exceeds 40 m. an additional width of 10 percent of the
dimension in excess of 40 m. shall be required on the side or rear open
space as the case may be:
Provided that, no such increase in
additional open space shall be necessary if (a) it is front open margin
space, or (b) when only store rooms and stairways derive light and
ventilation from the open space.
Provided further that-
- The open space for separation between
any building and a single storeyed accessory building shall not be
less than 1.5 m.
- The minimum distance between any two
ground floor structures in Public Housing/ High Density Housing
shall be 4.5m., if habitable rooms derive light and ventilation from
the intervening space; if not, the distance may be reduced to 1.5 m.
- Except where the plot size is less
than 2500 sq.m. the marginal open space in a plot abutting the
amenity/ recreational open space in the same layout shall not be
less than 3 m.
- Where the amenity open space being
accessible from all the layout plots does not have an exclusive
means of access, the rear marginal open space shall not be less than
3m.
|
Open Spaces for Tower like
Structure - Not withstanding the
provisions of regulation no15.1.4. tower like structure may be permitted
only with 6 (six) meter minimum open space at the ground level and one
set back at the upper levels provided that the total height does not
exceed 37.5 the minimum open space at ground level shall be 12 M. with
two setbacks at upper level. The terrace created by the setback
shall be accessible through a common passage and or common staircase
only. For height more than 24 meter shall need no objection
certificate from Director of Microwave Project, Nagpur Telephone, Fire
Brigade and Civil Aviation Authority.
|
Open Spaces separate for Each
Building or Wing - The Open spaces
required under these regulation shall be separate or distinct for each
building and where a building has two or more wings, each wing shall
have separate or distinct open spaces according to these regulations for
the purpose of light and ventilation of the wings.
|
|
Interior Open Spaces (Chowk) |
Inner Chowk -
The whole of one side of every room excepting bath,
W.C. and store room and not abutting on either the front, rear or side
(s) open spaces (see regulation No. 17.12.2) shall abut on an internal
open space (Courtyard, inner chowk) whose minimum width shall be 3 m.
Further inner chowk shall have an area
at all levels of chowk of not less than the square of the 1/5th the
height of the highest wall abutting the chowk. Provided that
when any room (excluding staircase bay and bathrooms and water closet
(see regulation no. 15.2.1.1) is dependent for its light and
ventilation on an inner chowk, the dimension shall be such as is
required for each wing of the building.
Where only water closet and bathroom
are abutting on the interior open space, the size of the interior open
space shall be in line with the provision for ventilation shaft as
given in regulation no. 17.12.4.
Outer Chowk - The minimum width of outer chowk (as distinguished from
its depth) shall be not less than 2.4 m. if the width of outer chowk
is less than 2.4 m. then it shall be treated as a notch and the
provisions of outer chowk shall not apply. However, if the depth
of outer chowk is more than the width, the provisions of regulation
No. 15.1.6 shall apply for the open spaces to be left between the
wings.
|
Area and Height Limitations - The area and height limitations through covered
area, height of buildings and number of storeys, floor space index,
facing different road widths shall be as given in Appendix 'N' and
Regulation No. 15.5.
|
Exemption to Open Spaces/ Covered Area
The following exemption to open spaces
shall be permitted:
- Projections into Open Spaces- Every open space provided
either interior or exterior shall be kept free fro any erection
thereon and shall be open to the sky and no cornica, chajja, roof
or weather shade more than 0.75 m. wide shall overhang or project
over the said open space so as to reduce the width to less than
the minimum required. However, slopping chajja provided over
balcony/ gallery etc. may be permitted to project 0.3 m. beyond
balcony projections at an angle of 30 degree from horizontal
level.
- A canopy not exceeding 5 m. in length and 2.5 m. in width in the
form of cantilever and unenclosed over the main entrance providing
a minimum clear height of 2.1 m. below the canopy. The
conopy shall not have access from upper floors (above floors), for
using as sitting out place. There shall be a minimum
clearance of 1.5 m. between the plot boundaries and canopy.
- Projections/Balconies: Balcony or balconies of a minimum
width of 1.00 m. may be permitted free of FSI at any floor, not
more than 15% of the floor area and such balcony projection shall
be subject to the following conditions.
- In non-congested area, no balcony shall reduce the marginal
open space to less than 3 m. In congested area balcony
may be permitted on upper floors projecting in front setbacks
except over lanes having width of 4.50 or less. No
balcony shall be allowed on ground floor which shall reduce
minimum required front setback or marginal open space.
The width of the balcony will be measured perpendicular to the
building line admeasured from that line to the balcony's outer
most edge.
- Balconies may be allowed to be enclosed, when enclosed 1/3
of the area of their faces shall have glass shutters on the
top and the rest of the area except the parapet shall have
glazed shutters.
- The dividing wall between the balcony and the room may be
permitted to be removed on payment of premium as prescribed by
the Municipal Commissioner from time to time.
- A projection of 15 cm. on terrace
level shall be allowed through out periphery of the building.
|
The following shall not be included in
covered area for F.S.I. and Build-up area calculations:
In addition to rule 15.4.1.(a), (b) and
(c) and 17.6.3. the following shall not be included in covered area of
F.S.I. and built up area calculations.
- Multi-storeyed stilt floor space constructed under a building
shall be allowed to be used as parking subject to the height
restrictions in that area.
- Electric cabins or sub station, watchman booth of minimum size of
3.00 Sq. Mt. with a minimum width or diameter of 1.2 m. pump house,
garage shaft, space required for location of fire hydrants, electric
fittings and water tanks.
- Projections as specifically exempted under these rules.
- A basement in two tiers construction under a building and used for
air-conditioning plant/ meter room, electric sub station and parking
spaces for the plots of the size more than 1000 Sq.M. in non
congested area only, (use accessory to the principal use). (In
non-congested area for starred hotels with rating three and above,
hospitals of charitable trusts, cinema theatres for an area as per
technical requirements with special written permission of the
Commissioner/Chairman of NIT).
- Areas covered by staircase rooms for stair flights of width 0.75
m. and above in case of row housing, pent houses and duplexes, 1.2
m. and above in case of residential/commercial buildings and 2 m.
and above in case of assembly halls, area of staircase flights,
midlandings and floor-landings, staircase passages irrespective of
width of staircase subject to payment of premium to be decided by
the Municipal Commissioner/Chairman and without any premium for
Government, Semi-government buildings, Educational and Hospital
buildings of Charitable Trusts and buildings constructed for slum
dwellers under Slum Redevelopment Schemes.
Note:- Minimum width of staircase room and
flight shall be 1.2 m. except in case of Duplex and EWS Housing were
it shall be 0.75 m.
- Architectural features, chimneys and elevated tanks of permissible
area of fire escape stairways tanks of permissible area of fire
escape stairways and lifts with contilevered fire escape passages
according to the Chief Fire Officer's requirements. Lift room,
lift wells, lift lobbies subject to premium as decided by Municipal
Commissioner.
- Area of one office room of a cooperative housing society or
apartment owners association of size 4m x 3m. only on the ground
floor.
- Area of the sanitary block(s) consisting of a bathroom and water
closet for each wing of each floor of a building of a prescribed
dimensions deriving access from a common passage as required for the
use for domestic servants or staff engaged in the premises.
- Areas covered by (i) lofts, (ii) Meter rooms, (iii) Porches, (iv)
Canopies, (v) Air conditioning plant rooms, (vi) Electric
sub-stations, (vii) Service floor to height not exceeding 1.5 m. for
hotels rating with tree stars and above with the special permission
of the Commissioner/Chairman.
- Area of structure for an affluent treatment plant is required as
per the requirements of the Maharashtra Pollution Control Board or
other relevant authorities.
- Areas covered by service ducts, pumps, rooms, electric
sub-station, stilts and additional amenity of lift.
- Area of one milk booth under the public distribution system in a
building layout of area exceeding 0.4 Hs. with the permission of the
Commissioner/Chairman.
- Rockery, well and well structures, plant, nursery, water pool,
swimming pool, (if covered) platform round a tree, fountain bench,
chabutars with open top and unclosed sides by walls, ramps, compound
wall, gate side, swing, overhead water tank on top of buildings,
Provided that the distance between terrace and sockpit of tank is
less than 1.50 m.
- Area of one public telephone booth and one telephone exchange
(PBX) per building with the permission of the Commissioner/Chairman.
- Area of one room for installation of telephone concentrates as per
requirement of Telephone Authority but not exceeding 20 Sq. Mt. per
building with the permission of the Commissioner/Chairman.
- Area of seperate letter box on the ground floor of residential and
commercial buildings with five or more storeys to the satisfaction
of the Commissioner/Chairman.
- Area covered by new lift and passage thereto in an existing
building with height up to 16 m. in gaothan/congested area.
- Area of covered passage of clear width not more than 1.52 m. ( 5
Ft. ) leading from a lift exists at terrace level to the existing
staircase so as to enable decend to lower floors in a building to
reach tenements not having direct access to a new lift in a building
without an existing lift.
- Artium or entrances of any size and passage more than 1.5 m. width
in shopping malls, public buildings.
NOTE: This rule shall not be applicable for the
building proposals where occupancy certificates have been granted
prior to issue of these regulations. Provided further that where
a permissible FBI has not been exhausted in the case of existing
building and cases decided by the corporation, prior to comming into
force of these modified regulations, provisions about the exclusion
from FSI computation as in these regulations will be available for
construction of remaining balance FSI on site.
|
The height and number of storeys shall be
related to provisions of F. S. 1. as given in these regulations and the
provisions of open spaces and the following -
- The maximum height of building shall
not exceed 1.5-times total of the width of road abutting and the
front open space subject to the NOC of Director of Microwave
Project, Nagpur Telephone, Civil Aviation & Chief Fire Officer,
Nagpur in case of building exceeding 15 m. in height;
- If a building abuts on two or more
streets of different widths, the building shall be deemed to face
upon the street that has the greater width and the height of
building shall be regulated by the width of the street and may be
continued to this height to a depth of 24 m. along the narrower
street.
- In case of congested area the maximum
height of building shall be as under -
|
Sr. |
Road Width |
Maximum
Permmissible Height |
|
1. |
Upto 6 m. |
1.5 times width of
the road + front marginal open space within the premises. |
|
2. |
6 m. to 10 m. |
1 0 m. + front
marginal distance within the premises. |
|
3. |
Other roads above 10 m. |
Sum of the width
of the road + front marginal distance. |
- For building in the vicinity of
aerodromes the maximum height of such buildings shall be subject to
values framed by the Civil Aviation Authorities and provisions of
Table 7;
- In addition to (d) for industrial
Chimneys coming in the Air-port zone, it shall be of such height and
character as prescribed by Civil Aviation Authorities and all
Industrial Chimneys shall be of such character as prescribed by the
Chief Inspector of Steam Boilers and Smoke Nuisance; and
- Buildings intended for hazardous
godowns storage of inflammable materials of storage of explosives
shall be single storied structures only.
|
- For the purpose (a) the width of the street may be prescribed
width of the street, shown on Development Plan or width resulting
from the prescription of a regular line of street under the
relevant act whichever is more, provided the height of the
building does not exceed twice the sum of the width of existing
street plus the open space between the existing street and the
building (2w + open space).
- Further to provisions of (i) the width of the open space between
the street and the buildings shall be calculated by dividing area
of land between the street and the building by the length of the
front face of the building.
|
Height Exemptions - The following
appurtenant structures shall not be included in the height of the
building:
Roof tanks and their supports,
ventilating, air conditioning, lift rooms and similar service equipment;
stair cover, chimneys and parapet walls and architectural features not
exceeding 1 m. in height.
|
|
TABLE 7
Aerodrome Vicinity Height Restrictions
| Sr. No. |
Limits of distance from the
Aerodrome reference point of buildings, structure or installations
measured horizontally |
Permissible Height of
building, structure or installation from Aerodrome reference point |
Remark |
| 1. |
2500 m. |
Nil |
* |
| 2. |
2500 m.
3000 m. |
12 m. |
* * |
| 3. |
3000 m.
3600 m. |
24 m. |
* |
| 4. |
3600 m.
4250 m. |
36 m. |
|
| 5. |
4250 m.
5000 m. |
48 m. |
|
| 6. |
5000 m.
6000 m. |
60 m. |
|
| 7. |
6000 m.
7500 m. |
90 m. |
|
| 8. |
7500 m.
8500 m. |
120 m. |
|
| 9. |
8500 m.
22000 m. |
150 m. |
|
* See note 1 & 2
below,
* * See note 2 below.
Note -
- Except with the concurrence of the local Aerodrome Authority
- No tree shall be planted within the limits of the distances
indicated
- Irrespective of their distances from the Aerodrome, even beyond
the 22 km., no masts or similar type of installations exceeding 152
m. in height should be erected without the prior permission of the
Director General of Civil Aviation.
- No Building, structure or installation exceeding the height
specified in Table-7 shall be permitted without prior consultation
with the concerned Civil or Military Aerodrome
- The location of slaughter house/ butcher house and other areas for
activities like depositing of garbage dumps which would generate the
collection of high flying birds like eagles/hawks etc. shall not be
permitted within a radius of 10 km. from Aerodrome reference point.
|