SPECIAL REQUIREMENTS OF OCCUPANCIES

  • Special requirements of Educational buildings

No class room shall admeasure less than 38 sq. m. with a minimum dimension of 5.50 m.
The height of any class room shall not be less than 3.60 m.

Exit Requirements -  This shall conform to regulation no. 19 and 19.3.5

Requirements of Water Supply, Drainage and Sanitation.-This shall conform to requirements of regulation Nos. 26.2 and 26.3 and Table 12 and 17.

Parking spaces - This shall conform to Table 8.

  • Special Requirements of Institutional Buildings (Hospital, Maternity Homes and Health Centres, Sanitaria).

Any Special ward in the hospital building shall not admeasure less than 9.0 sq. m. in area with no side less than 3m.
Area of the general wards shall not admeasure less than 40 sq. m. with no side less than 5.5. m.
Every building shall have a refuge area of minimum 7.50 sq. m. size with cover on top and enclosed
on at least three sides. The same shall not be allowed in marginal open spaces. Modern method of incineration of the refuge may be adopted.

Exit Requirements - This shall conform to regulations No. 19 and 19.3.5

Requirements of Water Supply, Drainage and Sanitation - This shall conform to requirements of Regulation No. 26.2 and 26.3 and Tables 12, 18 and 19.

Parking Spaces - This shall conform to Table-8.

  • Special Requirements of Cinema Theatre (Assembly Halls)

They shall conform to the provisions of Maharashtra Cinema (Regulations) Rules, 1966, as amended from time to time.

Exit Requirements - This shall conform to regulations No. 19 and 19.3.5

Requirements of Water Supply, Drainage and Sanitation - This shall conform to requirements of Regulation No. 26.2 and Tables 12, 13 and 22.

Parking Spaces - This shall conform to regulation No. 16, 16.7 and Table-8.

  • Special Requirements of Mercantile Buildings.

Minimum area of shop shall be 6 Sq. m. in R-1 zones with a minimum width of 2.0 m. and 10 Sq. m. in R-2 and other zones with a minimum width of 3 m.

  • Special requirements of Industrial Building.-

In addition of provisions of these regulations, regulations prescribed under Factory Act shall be applicable.

In the case of industrial Buildings with different operations/processes, the different (gaseous, solid, liquid) effluents shall be so treated, subject to the approval of Maharashtra Prevention of Water Pollution Board and Chief Inspector of Steam Boilers and Smoke Nuisance, before letting it out on to the air, ground or water course.

Exit Requirements - This shall conform to regulations No. 19 and 19.3.5

Requirements of Water Supply Drainage and Sanitation - This shall conform to regulation No. 26.2 and 26.3 and Tables 12,13 and 25.

Parking spaces/Loading and unloading spaces - This shall conform to regulation No. 16, 16.5 and Table-8.